Journal: :iranian journal of medical physics 0
mohammad taghi bahreyni toossi medical physics research center, school of medicine, mashhad university of medical sciences, mashhad, iran department of medical physics, school of medicine, mashhad university of medical sciences, mashhad, iran

introduction computed tomography scans are a very important tool for diagnosis and assessment of response to treatment in the practice of medicine. ionizing radiation in medical imaging is undoubtedly one of the most powerful diagnostic tools in medicine. yet, as with all medical interventions, there are potential risks in addition to the clear potential benefits. materials and methods two refe...

Journal: :iranian journal of radiation research 0
a. solimanian radiation dosimetry and monitoring group agricultural, medical and industrial research school (amirs), nuclear science and technology research institute (nstri), atomic energy organization of iran (aeoi) - karaj, iran m. ghafoori radiation dosimetry and monitoring group agricultural, medical and industrial research school (amirs), nuclear science and technology research institute (nstri), atomic energy organization of iran (aeoi) - karaj, iran

background: absolute dosimetry of external beam radiotherapy is carried out by the use of ionization chambers. these chambers must be calibrated at a standard dosimetry laboratory before any use in clinical dosimetry. the secondary standard dosimetry laboratory of iran (ssdl) has the duty of calibrating the ionization chambers used in radiotherapy centers in iran. materials and methods: the pre...

Journal: :iranian journal of radiation research 0
m.a. gadhi bahawalpur institute of nuclear medicine and oncology (bino) bahawalpur, pakistan s.a. buzdar department of physics, the islamia university of bahawalpur, pakistan m. afzal department of physics, the islamia university of bahawalpur, pakistan sh. fatmi bahawalpur institute of nuclear medicine and oncology (bino) bahawalpur, pakistan m.s. akhtar bahawalpur institute of nuclear medicine and oncology (bino) bahawalpur, pakistan a.h. nizamani department of physics, university of sind, jamshoro, hyderabad, pakistan

background: the effectiveness and safety of brachytherapy treatment is mainly concerned with the calibration of sources and their traceability to internationally accepted standards. secondary standard dosimetry laboratory (ssdl) does not offer calibration of ionization chambers with gamma-ray spectrum of high dose rate source 192ir . this work has been carried out to calibrate the high dose rat...

Journal: :iranian journal of radiation research 0
s. abdollahi reza radiotherapy oncology center, mashhad, iran m. mohammadi department of medical physics, hamadan university of medical science, hamadan, iran a. ebrahimzadeh pezeshki reza radiotherapy oncology center, mashhad, iran z. alizadeh reza radiotherapy oncology center, mashhad, iran

background: in order to deliver the precise dose to the target in radiotherapy, absorbed dose to water at the reference point should be assessed. when the calibration procedure is performed for a reference dosimeter in the 60co beam of a secondary standard dosimetry laboratory (ssdl), the total uncertainty in absorbed dose to water (dw) is estimated to be approximately 1.5%. this study attempts...

Journal: :iranian journal of radiation research 0
a. iftikhar cenar cancer hospital, bmc complex, brewery road, po box 17, quetta pakistan

background: the aim of this work was to study the output factors for linac using different ionization chambers and build up caps. materials and methods: output factors were measured for open square fields (3 × 3 cm to 40 × 40 cm) defined by collimator jaws for 6 and 15 mv photon beams from a varian clinac 2100c accelerator were measured. the measurements in air were performed using compact cyli...

ژورنال: سنجش و ایمنی پرتو 2013

The development of a graphite ionization chamber in Iran is reported for first time, using graphite coatings collecting electrodes and guard rings. Its sensitive volume is about 200cm³, with a shape of a ring which is different from its older equivalents and a 7cm central hole that allows the passage of the direct radiation beam without attenuation. This kind of ionization chamber has alre...

ژورنال: سنجش و ایمنی پرتو 2020

According to International Atomic Energy Agency (IAEA) recommendations, the calibration of ionization chambers used for radiotherapy dosimetry follows the substitution method which demands the use of a reference ionization chamber. This work introduces the Design and fabrication of cylindrical ionization chamber for dosimetry to be used by standard dosimetry laboratories. The result of the qual...

Kourosh Arbabi, Zahra Saberi

Introduction: Due to its simplicity, fast response and high reliability, ion chamber detectors are one of the most suitable dosimetry instruments for X and gamma rays. The dosimeter    of photon beams, which used in radiotherapy centers, requires high accuracy and should pass requirements of IEC 60731 standards. About 80 percent of the IEC 60731 standard tests such as stabil...

Journal: :iranian journal of medical physics 0
hamidreza shabani m.sc. student of medical physics, department of medical physics, tehran university of medical sciences, tehran, iran mahmood allahverdi associated professor, medical physics dept., tehran university of medical sciences, and radiotherapy physics dept., of the cancer institute, tehran, iran mahbod esfahani physisist of the radiotherapy physics department of the cancer institute, tehran, iran mehdi aghili associate professor, radiotherapy and oncology department of the cancer institute, imam khomeini hospital, tehran, iran abbas takavar professor, medical physics dept., tehran university of medical sciences, tehran, iran mohammd reza taghizade m.sc. of medical physics, imam khomeini medical imaging center, gilan university of medical sciences, some’e-sara, iran

introduction: delivering maximum dose to tumor and minimum dose to normal tissues is the most important goal in radiotherapy. according to icru, the maximum acceptable uncertainty in the delivered dose compared to the prescribed dose should be lower than 5%, and this is because of the relationship between absorbed dose, tumor control and normal tissue damage. absorbed dose accuracy is investiga...

Mohammad Bahrami Mohammad Taghi Bahreyni Toossi,

Introduction Computed Tomography scans are a very important tool for diagnosis and assessment of response to treatment in the practice of medicine. Ionizing radiation in medical imaging is undoubtedly one of the most powerful diagnostic tools in medicine. Yet, as with all medical interventions, there are potential risks in addition to the clear potential benefits. Materials and Methods Two refe...